Thermocore 45000 BTU AC-Heat 21 SEER
45000 BTU ENERGY STAR Ceiling Cassette Split AC
22 SEER Efficiency w/ Heat Pump Technology The 45000 BTU Quint-Zone INVERTER mini split AC with Ceiling Cassette can cool or heat Five separate zones (5 x 9000 BTU) for a total coverage area of 2000 ft² (
Five 400 ft² areas). The Air handlers are discreetly recessed into a ceiling panel - only the grill is visible. 22 SEER Inverter technology with ENERGY STAR Certification provides the benefits of low operation temperatures, rapid cooling / heating, as well as maximum energy efficiency. R454B Pre-charged - 5 X 15' Installation linesets Included.
Technical Data:
System Includes:
- 45,000 BTU INVERTER Cooling Capacity (9k x 5)
- 45,000 BTU INVERTER Heat Pump Capacity (9k x 5)
- 22 SEER - 11.3 HSPF - AHRI / ENERGY STAR *
- Quint-Zone Ceiling Cassette Setup
- Pre-Charged with R454B for 150ft of Lineset
- 1 Year Parts - 5 Year Compressor Warranty
- Indoor Unit - Cassette Air Handlers
- Outdoor Unit - Condenser of 44000-54000 BTUs
- Digital Multi-function LCD Remote Control
- Wall Mounted thermostats.
- Installation Kit with 15' x 5 of lineset. >>>
- Product and Installation Manual. >>>
** Extend 1 year parts - 5 year warranty package to 3 year part / 7 year warranty for $140 / year.
Top Line Features:
- 21 SEER - 10.80 HSPF - ENERGY STAR
- Most Energy Efficient Quint-Zone Series on Market
- Quint Air Handlers Mounts Discreetly in Ceiling
- Dry-Mode removes moisture w/o affecting room temp
- Cross Flow Technology reduces noise output
- Freon Leak Detection > Notification system
- Low Ambient Temperature Operation (-22° F)
- Restart IC: Settings restored Following Power Outage
- Follow-Me Function tracks Remote Location
Indoor Unit (evaporator) specs
Capacity9000 BTU
Air Flow (Hi/M/Lo)374/301/257 cfm
Power Supply208-230~1-60
Input Power45W
Noise Output (Hi/M/Lo)41/37/33 dBA
Liquid / Gas1/4" x 3/8"
Weight31.97/38.14 lbs
Dimensions (W x D x H)23.47 x 23.47 x 8.97 in.
Outdoor Unit (condenser) specs
Model Number T7HH25Q-H248-C
Compressor Brand TOSHIBA - GMCC
Capacity 17000-44000 BTU
Maximum AHU Capacity 54000 BTU
Air Flow 3057 CFM
Power Supply 230 V / 60 Hz / 1Ph
Fuse Size 40A
SEER 22
EER 12.2
HSPF4 11.3
Sound Level 64 dBA
Operating Temp Range -22 F to 122 F (cool and heat)
Refrigerant R454B / 134oz Charge
Liquid / Gas 1/4" x 3/8" (3) + 1/4" x 1/2" (2)
Max Lineset Length (1 zone) 115 ft
Max Lineset Length (all zones) 263 ft
Pre-Charge Length 125 ft (25 ft x 5)
Weight 212 lbs
Dimensions (W x D x H) 38.58 × 16.4 × 38.4 inches
Install Kit Contents:
- 15 Feet Flared Copper Tubing x 5
- 15 Feet Pipe Insulation x 5
- 15 Feet Electrical Wire x 5
- Drain Pipe (outdoor)
- Outdoor Condenser Rubber pads
- Wall Bracket for Indoor Unit x 5
- Brass Adaptors for Alternate lineset sizes
- Installation and User Manuals
*** Extend 15 foot copper lineset to 25-30-40-50-65 feet. Just $4.50 / additional foot***
WHAT IS DC INVERTER? DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split*It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below >
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. 1 YEAR PARTS WARRANTY CAN BE EXTENDED TO 2 YEARS FOR AN ADDITIONAL $140.00